WELDED STEEL ARC STUDS
TENSILE & TORQUE STRENGTHS

WELD BASE DIAMETER (Inches)
TORQUE
(Foot Pounds)
welded steel arc studs tensile and torque strengths
TENSILE LOAD (Pounds)
 

Graphs are based on 60, 000 psi strength steel. Of course in actual practice, a stud should never be used at its hield load. A factor or safety must be applied. It is generally recommended that stud be used at no more than 60% of yield. However. the factor of safety may vary up or down, depending of the particular application. The user will make this determination. If further assistance is needed, contact MIDWEST FASTENERS Customer Service Department.

Scale along the top of each graph represents weld base diameter in inches, while the one at the graph's bottom edge shows tensile load in pounds. A separate line is ploted
for each thread diameter. The solid portion of each line terminates at a small dot which represents the tensile yield of the national course thread. A dashed line is then extended to a second dot at the tensile yield load of the national fine thread.

 