MIDWEST Fasteners Capacitor Discharge weld studs, once stud welded in place, present a range of physical qualities in relation to the studwelded fastening method and load strength. These include particular load strengths for the stud welded fastener based on material (Mild Steel, Stainless, Brass and Aluminum Weld Studs primarily) and weld stud diameter or configuration. These include weld stud loads in torque (Inch Lbs.), tensile load (Lbs.) and shear load (Lbs.).


STUD

MATERIAL

STUD

SIZE
MAXIMUM
FASTENING
TORQUE
(Inch Lbs.) *
ULTIMATE
TENSILE
LOAD
(Lbs,)
MAXIMUM
SHEAR
LOAD
(Lbs.)
LOW-CARBON,
COPPER-FLASHED
STEEL
6-32
6
500
375
8-32
12
765
575
10-24
14
960
720
1/4-20
43
1750
1300
5/16-18
72
2900
2200
3/8-16
106
4300
3250
STAINLESS
STEEL
304
6-32
10
790
590
8-32
20
1260
940
10-24
23
1530
1150
1/4-20
75
2880
2160
5/16-18
126
3750
5350
3/8-16
185
4850
7150
ALUMINUM
ALLOY
1100
6-32
2.5
200
125
8-32
5
295
185
10-24
6.5
380
235
1/4-20
21.5
670
415
5/16-18
36
1125
695
3/8-16
53
1660
1000
ALUMINUM
ALLOY
6061
6-32
6.5
350
160
8-32
13
560
229
10-24
19
670
310
1/4-20
40
1240
679
5/16-18
70.5
2025
1210
3/8-16
100
2985
1750
BRASS
70-30 (260)
65-35 (268)
6-32
8
600
390
8-32
16
860
560
10-24
18.5
1040
680
1/4-20
61
1950
1275
5/16-18
102
3280
2140
3/8-16
150
4800
3160
 
*These values should develop fastener tension to slightly less than yield point.
Request for Quote

Please fill in the form below to receive a prompt quote or call 800-852-8352.

Name *

Company Name *

Zip *

Email Address *

Phone *

Project Details *

Please attach any drawings or other information that may assist us.

ATTACH FILE 1

ATTACH FILE 2

Maximum attachment size: 20 MB

* Required Fields

Submit button



Copyright ©, 2010 Midwest Fasteners, Inc.