800.852.8352 Fax: 937.866.4174
Midwest Fasteners, Inc. 450 Richard St. Miamisburg, OH 45342
|
MIDWEST FASTENER CAPACITOR DISCHARGE (CD) STUD LOAD STRENGTHS
MIDWEST Fasteners Capacitor Discharge weld studs, once stud welded in place, present a range of physical qualities in relation to the studwelded fastening method and load strength. These include particular load strengths for the stud welded fastener based on material (Mild Steel, Stainless, Brass and Aluminum Weld Studs primarily) and weld stud diameter or configuration. These include weld stud loads in torque (Inch Lbs.), tensile load (Lbs.) and shear load (Lbs.).
STUD
MATERIAL
|
STUD
SIZE
|
MAXIMUM
FASTENING
TORQUE
(Inch Lbs.) *
|
ULTIMATE
TENSILE
LOAD
(Lbs,)
|
MAXIMUM
SHEAR
LOAD
(Lbs.) |
|
LOW-CARBON,
COPPER-FLASHED
STEEL |
6-32 |
6 |
500 |
375 |
8-32 |
12 |
765 |
575 |
10-24 |
14 |
960 |
720 |
1/4-20 |
43 |
1750 |
1300 |
5/16-18 |
72 |
2900 |
2200 |
3/8-16 |
106 |
4300 |
3250 |
|
STAINLESS
STEEL
304 |
6-32 |
10 |
790 |
590 |
8-32 |
20 |
1260 |
940 |
10-24 |
23 |
1530 |
1150 |
1/4-20 |
75 |
2880 |
2160 |
5/16-18 |
126 |
3750 |
5350 |
3/8-16 |
185 |
4850 |
7150 |
|
ALUMINUM
ALLOY
1100 |
6-32 |
2.5 |
200 |
125 |
8-32 |
5 |
295 |
185 |
10-24 |
6.5 |
380 |
235 |
1/4-20 |
21.5 |
670 |
415 |
5/16-18 |
36 |
1125 |
695 |
3/8-16 |
53 |
1660 |
1000 |
|
ALUMINUM
ALLOY
6061 |
6-32 |
6.5 |
350 |
160 |
8-32 |
13 |
560 |
229 |
10-24 |
19 |
670 |
310 |
1/4-20 |
40 |
1240 |
679 |
5/16-18 |
70.5 |
2025 |
1210 |
3/8-16 |
100 |
2985 |
1750 |
|
BRASS
70-30 (260)
65-35 (268) |
6-32 |
8 |
600 |
390 |
8-32 |
16 |
860 |
560 |
10-24 |
18.5 |
1040 |
680 |
1/4-20 |
61 |
1950 |
1275 |
5/16-18 |
102 |
3280 |
2140 |
3/8-16 |
150 |
4800 |
3160 |
|
|
| |
| *These values should develop fastener tension to slightly
less than yield point. |
|