800.852.8352
Midwest Fasteners, Inc. 450 Richard St. Miamisburg, OH 45342
|
MIDWEST FASTENER CD STUD
LOAD
STRENGTHS
STUD
MATERIAL
|
STUD
SIZE
|
MAXIMUM
FASTENING
TORQUE
(Inch Lbs.) *
|
ULTIMATE
TENSILE
LOAD
(Lbs,)
|
MAXIMUM
SHEAR
LOAD
(Lbs.) |
|
LOW-CARBON,
COPPER-FLASHED
STEEL |
6-32 |
6 |
500 |
375 |
8-32 |
12 |
765 |
575 |
10-24 |
14 |
960 |
720 |
1/4-20 |
43 |
1750 |
1300 |
5/16-18 |
72 |
2900 |
2200 |
3/8-16 |
106 |
4300 |
3250 |
|
STAINLESS
STEEL
304 |
6-32 |
10 |
790 |
590 |
8-32 |
20 |
1260 |
940 |
10-24 |
23 |
1530 |
1150 |
1/4-20 |
75 |
2880 |
2160 |
5/16-18 |
126 |
3750 |
5350 |
|
ALUMINUM
ALLOY
1100 |
6-32 |
2.5 |
200 |
125 |
8-32 |
5 |
295 |
185 |
10-24 |
6.5 |
380 |
235 |
1/4-20 |
21.5 |
670 |
415 |
5/16-18 |
36 |
1125 |
695 |
3/8-16 |
53 |
1660 |
1000 |
|
ALUMINUM
ALLOY
6061 |
6-32 |
6.5 |
350 |
160 |
8-32 |
13 |
560 |
229 |
10-24 |
19 |
670 |
310 |
1/4-20 |
40 |
1240 |
679 |
5/16-18 |
70-5 |
2025 |
1210 |
3/8 16 |
100 |
2985 |
1750 |
|
BRASS
70-30 (260)
65-35 (268) |
6-32 |
8 |
600 |
390 |
8-32 |
16 |
860 |
560 |
10-24 |
18.5 |
1040 |
680 |
1/4-20 |
61 |
1950 |
1275 |
5/16-18 |
102 |
1280 |
2140 |
3/8-16 |
150 |
4800 |
3160 |
|
|
| |
| *These values should develop fastener tension to slightly
less than yield point. |
|

Please fill in the form below to receive a prompt quote or call 800-852-8352.
|